Charging Instructions
| Recommended Charge Current | Cyclic Application |
| - With Temperature Compensation | 15.0 A Max. |
| - Without Temperature Compensation | 7.5 - 15.0 A |
| Charge Voltage (12 Volts) | 14.4 - 14.9 V |
| Bulk Charge | 14.7 V |
| Absorption Charge | 14.7 V |
| Float Charge | 13.8 V |
| Temperature Compensate Factor | -4 mV/°C/Cell |
Operating Temperature
| Discharge : | -15°C~45°C |
| Charge : | -15°C~45°C |
| Storage : | -15°C~45°C |
DO NOT charge at temperature corrected voltages above 15 Volts (2.5 Volts/cell).
Use of voltage controlled charger is a requirement for warranty coverage.
For best cycle life, limit discharge to less than 50% of the batterys 20 hour capacity.
Applications
General Features
Dimensions and Weight
| Length(mm) | 260 |
| Width(mm) | 169 |
| Height(mm) | 211 |
| Total Height(mm) | 216 |
| Approx. Weight(Kg) | 26.2 |