Charging Instructions
Recommended Charge Current
Charge Voltage (12 Volts) Bulk Charge Absorption Charge Float Charge Temperature Compensate Factor | Cyclic Application 59.4 A Max. 33.0 - 59.4 A 7.2 - 7.45 V 7.35 V 7.35 V 6.85 V -4 mV/°C/Cell |
---|
Operating Temperature
Discharge: Charge: Storage: | -15°C~45°C -15°C~45°C -15°C~45°C |
---|
DO NOT charge at temperature corrected voltages above 7.5 Volts (2.5 Volts/cell).
Use of voltage controlled charger is a requirement for warranty coverage.
For best cycle life, limit discharge to less than 50% of the batterys 20 hour capacity.
Applications
General Features
Dimensions and Weight
Length(mm) Width(mm) Height(mm) Total Height(mm) Approx. Weight(Kg) | 295 178 354 360 46.8 |
---|